Highlights:
- 16 port Gigabit Layer2+ full managed switch architecture.
- Supports NWay protocol for speed (10/100/1000Mbps) and duplex mode (half/full) auto-detection
- Supports back-pressure (half duplex), flow control (IEEE 802.3x and IEEE 802.3az Energy Efficient Ethernet)
- VLAN 4K Static / Port-Based / Tagged Based / Protocol / Voice VLAN / 802.1ad Q-in-Q
- Link Aggregation static link / LACP / Algorithm MAC based or IP based
- IGMP Snooping 256 groups IGMP v1/v2/v3, Fast Leave
- QoS (QoS>QoS multi-label, queue config, QoS mapping)
- Stormcontrol
- Total fanless, no more annoying noises...
- 19 "inch angle or wall/table mounting possible
ALL-SG8618M is a 16* 10/100/1000M RJ45 ports and 2*100/1000M SFP fiber slot ports L2+ managed Ethernet fiber switch , built-in 35W power supply. Support 1U/19 inch rack installation.It is programmed for advanced switch management functions such as 802.1Q VLAN and Q-in-Q VLAN, Multiple Spanning Tree protocol (MSTP), loop and BPDU guard, IGMP snooping, and MLD snooping. Also, the Link Layer Discovery Protocol (LLDP) is the Layer 2 protocol included to help discover basic information about neighboring devices on the local broadcast domain. It provides a quick, safe and cost-effective Ethernet network solution for small businesses and enterprises.
Solution for IPv6 Networking With the IPv6/IPv4 dual stack and other management functions, ALL-SG8618M is the best choice for IP CCTV surveillance, VoIP and wireless solution providers to develop the IPv6 network. Meanwhile they help the SMBs to upgrade their network infrastructures to the IPv6 era without any extra investment.
Robust Layer 2 Features
ALL-SG8618M can be programmed for advanced Ethernet fiber switch management functions, such as port aggregation, Q-in-Q VLAN, Spanning Tree Protocol, QoS, bandwidth control, ERPS IGMP/MLD snooping etc. The ALL-SG86xx series allows the operation of a high-speed trunk combining multiple ports.
Powerful Security Functions ALL-SG8618M provides a comprehensive access control list (ACL) for enforcing security to the edge. It can be used to restrict to network access by denying packets based on source and destination IP address, TCP/UDP port number or defined typical network applications. Its protection mechanism also comprises 802.1x Port-based and MAC-based user and device authentication. With the private VLAN function, communication between edge ports can be prevented to ensure user privacy.
Enhanced Security and Traffic Control ALL-SG8618M supports DHCP Snooping, IP Source Guard and Dynamic ARP Inspection functions to prevent IP snooping from attack and discard ARP packets with invalid MAC address. The network administrator can now construct highly-secure corporate networks with considerably less time and effort than before.
User-friendly Secure Management For efficient management, ALL-SG8618M is a managed switch, equipped with console, web and SNMP management interfaces. With management interface, ALL-SG8618M offers an easy-to-use, platform independent management and configuration facility. ALL-SG8618M supports SNMP and it can be managed via any management software based on the standard SNMP v1 or v2 Protocol. Meanwhile ALL-SG8618M offers Cisco-like command via Telnet or console port and customer doesn?t need to learn new command from these switches. Moreover,ALL-SG8618M offers the remotely secure management by supporting SSH, SSL and SNMP v3 connection where the packet content can be encrypted at each session.
Intelligent SFP DDM Function ALL-SG8618M support SFP-DDM (Digital Diagnostic Monitor) function that greatly helps network administrator to easily monitor real-time parameters of the SFP and SFP+ transceivers, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage.
Fast Recovery Redundant Ring for Critical Network Applications
The ALL-SG8618M supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced ITU-T G.8032 ERPS technology, Spanning Tree Protocol (802.1s MSTP), and redundant power input system into customer?s industrial automation network to enhance system reliability and uptime in harsh factory environments. In a certain simple Ring network, the recovery time of data link can be as fast as 20ms.
1588 Time Protocol for Industrial Computing Networks
The ALL-SG8618M is ideal for telecom and Carrier Ethernet applications, supporting MEF service delivery and timing over packet solutions for IEEE 1588 and synchronous Ethernet.
Technical Details:
Model |
ALL-SG8618M |
Copper Ports |
16 10/100/1000BASE-T RJ45 auto-MDI/MDI-X ports |
Fiber Ports |
2-100/1000BASE-X SFP interfaces, supports 100/1000Mbps dual mode |
Console Ports |
1 x RS-232-to-RJ45 serial port (115200, 8, N, 1) |
Switch Architecture |
Store-and-Forward |
Switch Fabric |
36Gbps/non-blocking |
Throughput |
23.819Mpps @64 bytes |
Address Table |
8K entries |
Share Data Buffer |
4.0 Mb |
Jumbo Frame |
9600 Bytes |
SDRAM |
1Gb |
Flash Memory |
128Mb |
Flow Control |
IEEE 802.3x pause frame for full-duplex,Back pressure for half-duplex |
Reset Button |
> 2 sec: Factory default and reset |
Power Supply |
100~240V AC, 50/60Hz, 4A (max.) |
Power Consumption |
12V, 45watts/1122 BTU |
LED Indicators |
Power: Green
Solid on- power work normal, off- power disconnected
System: Green
Blink-work normally, solid on- soft work abnormal, fast Blink- soft upgrade
10/100/1000T RJ45 Interfaces (Port 1 to Port 16): 1000 LNK/ACT (Green), 10/100 LNK/ACT (yellow)
Blink- port connected with data transmission; Solid on- port connected without data transmission
100/1000Mbps SFP Interfaces (Port 17 to Port 18): Green
Blink- port connected with data transmission; Solid on- port connected without data transmission
|
EMC |
Surge Immunity: IEC61000-4-5
ESD Protection: ESD IEC61000-4-2: EFT IEC61000-4-4
|
Dimension |
440x240x44.5mm |
Weight |
3.2kg |
Working Temperature |
-10°C to 45°C |
Storage Temperature |
-20°C to 70°C |
MTBF |
50,000hrs |
Layer 2 functions
Port configuration |
Auto-negotiation
Flow Control
Port Mirror: TX/RX/BOTH; Many-to-1 monitor
CPU Mirror
Traffic statistics
|
Link Aggregation |
Static link aggregation
LACP(Dynamic Trunk/Static Trunk)
Algorith based on Source/Destination MAC
Algorithm based on Source/Destination IP
|
MAC Table |
Aging Time
Static MAC address
Dynamic MAC address management
|
VLAN |
4094 Active VLANs
4094 VID
802.1Q Tag VLAN
Port VLAN
Protocol VLAN
MAC VLAN
Voice VLAN
802.1ad Q-in-Q tunneling
Private VLAN (Protected port)
GARP/GVRP
|
ACL |
256ACLs
L2, L3 e L4
Time-based ACL
IP ACL
MAC ACL
MAC-IP ACL
User-Defined ACL
ICMPv6
|
Spanning tree |
802.1D Spanning Tree Protocol (STP)
802.1w Rapid Spanning Tree Protocol (RSTP)
802.1s Multiple Spanning Tree Protocol (MSTP)
Loop Guard
Root Guard
TC-BPDU Guard
BPDU Guard
BPDU Filter
|
Ring Protection |
<20ms G.8032 ERPS Ring
Fast Ring
|
Multicast |
256 groups
IGMP v1/v2/v3 Snooping, Fast Leave
MLD Snooping
Multicast VLAN
IGMP filter
MVR
Multicast Routing
|
QOS |
8 mapping IDs to 8 level priority queues
CoS port-based
CoS 802.1p-based
CoS DSCP-based
Scheduling algorithms SP, WRR, SP+WRR
Storm Control (Broadcast, Multicast, Unknown Unicast)
Bandwidth control per port
SWRR, DWRR for Scheduling
Flow Redirect
Precedence
TOS
Rate Limiting(Ingress/Egress)
Stri Priority
|
Security Features |
Port Security
MAC address filter
ARP Association (Manual, ARP scanning, DHCP snooping)
ARP Protection
AAA
DAI
DoS (Denial of Service)
Classification of packages based on: End.MAC, IP End, TCP / UDP Ports,
Protocol Type;
802.1x Authentication (port-based e MAC-based)
TACACS/TACACS+ Authentication
RADIUS Authentication
DHCP Filter
Guest VLAN
SSLv2/SSLv3/TLSv1
SSHv1/SSHv2
Restriction of WEB access based on: IP Address, And. MAC and Port;
Port Isolation
Loopback detection
|
Management |
SNMP v1/v2c/v3 with Full Private MIBs
RMON 4 groups
WEB (HTTP/HTTPS)
CLI (Telnet, Console, SSHv1/v2)
Firmware upgrade via console/web/TFTP
Configuration Backup/Reload
Dual Firmware
LLDP
Configuration Export/Import
CDP Aware
OAM (IEEE802.3ah)
CFM (IEEE802.1ag)
SFlow
Telnet client
|
Synchronization,
IEEE1588
|
Support IEEE1588v2 transparent clock |
Other Features |
DNS Client
DHCP Relay
DHCP Client
DHCP Snooping
DHCP Option 66
DHCP Option 67
DHCP Option 82
NTP/SNTP Client
UPNP
UDLD
|
Maintenance |
Cable Diagnostics
Ping
SFP DDM (Digital Diagnostics Monitoring)
Thermal protection
System log (Local and Remote)
Memory and CPU Monitoring
Tracert /Tracert 6
|
Layer 3 functions
Static Routing |
IPv4 Unicast: Static Routing(Software Base)
IPv6 Unicast: Static Routing(Software Base)
|
IPV6 |
IPv6 neighbor discovery (ND)
Path maximum transmission unit (MTU) discovery
Internet Control Message Protocol (ICMP) version 6
TCPv6/UDPv6
Ping6
Telnet(v6)
Http/Https
Interface IPV6
ACL IPV6
|
|
| | Patchkabel RJ45 FTP(F/UTP) 0.25m grau, CAT5e, Synergy 21, | | | Patchkabel RJ45 FTP(F/UTP) 0.5m grau, CAT5e, Synergy 21, | | | Patchkabel RJ45 FTP(F/UTP) 1.0m grau, CAT5e, Synergy 21, | | | Patchkabel RJ45 FTP(F/UTP) 2m grau, CAT5e, Synergy 21, | | | Patchkabel RJ45 FTP(F/UTP) 3m grau, CAT5e, Synergy 21, | | | Patchkabel RJ45 FTP(F/UTP) 5m grau, CAT5e, Synergy 21, | | | Patchkabel RJ45 FTP(F/UTP) 7.5m grau, CAT5e, Synergy 21, | | | Patchkabel RJ45 FTP(F/UTP) 10m grau, CAT5e, Synergy 21, | | | Patchkabel RJ45, 15m grau, CAT5e, S-FTP(SF/UTP), Synergy 21, | | | Patchkabel RJ45, 0.25m grau, CAT5e, S-FTP(SF/UTP), Synergy | | | Patchkabel RJ45, 0.5m grau, CAT5e, S-FTP(SF/UTP), Synergy 2 | | | Patchkabel RJ45, 1.0m grau, CAT5e, S-FTP(SF/UTP), Synergy 2 | | | Patchkabel RJ45, 2m grau, CAT5e, S-FTP(SF/UTP), Synergy 21, | | | Patchkabel RJ45, 3m grau, CAT5e, S-FTP(SF/UTP), Synergy 21, | | | Patchkabel RJ45, 5m grau, CAT5e, S-FTP(SF/UTP), Synergy 21, | | | Patchkabel RJ45, 7.5m grau, CAT5e, S-FTP(SF/UTP), Synergy 2 | | | Patchkabel RJ45, 10m grau, CAT5e, S-FTP(SF/UTP), Synergy 21, | | | Patchkabel RJ45, CAT6 250Mhz, 0.25m grau, S-STP(S/FTP), LSZH, Synergy 21, | | | Patchkabel RJ45, CAT6 250Mhz, 0.5m grau, S-STP(S/FTP), LSZH, Synergy 21, | | | Patchkabel RJ45, CAT6 250Mhz, 1.0m grau, S-STP(S/FTP), LSZH, Synergy 21, | | | Patchkabel RJ45, CAT6 250Mhz, 2m grau, S-STP(S/FTP), LSZH, Synergy 21, | | | Patchkabel RJ45, CAT6 250Mhz, 3m grau, S-STP(S/FTP), LSZH, Synergy 21, | | | Patchkabel RJ45, CAT6 250Mhz, 5m grau, S-STP(S/FTP), LSZH, Synergy 21, | | | Patchkabel RJ45, CAT6 250Mhz, 7.5m grau, S-STP(S/FTP), LSZH, Synergy 21, | | | Patchkabel RJ45, CAT6 250Mhz,10m grau, S-STP(S/FTP), LSZH, Synergy 21, | | | Patchkabel RJ45, CAT6 250Mhz,15m grau, S-STP(S/FTP), LSZH, Synergy 21, | | | TP(RJ45) POE-Tester, at/af, Endspan/Midspan, standard, Synergy 21, |
Zurück |